1,458 research outputs found

    Vesting Verities and the Development Chronology: A Gaping Disconnect?

    Get PDF
    The purpose of this Essay is to identify some of the anomalies arising from the disjointed body of case law on vested rights, particularly as they affect phased developments. An Appendix is provided setting forth the development chronology, with selected court rulings at each step along the way to demonstrate the disparate nature of vesting jurisprudence

    Recognizing Vested Development Rights As Protected Property in Fifth Amendment Due Process and Takings Claims

    Get PDF
    The purpose of this Article is to demonstrate that a landowner possessing vested development rights under state law has a property interest and reasonable expectations which are entitled to great weight when determining the viability of the landowner\u27s Fifth Amendment takings claim or substantive due process claim

    Measurements of the methane relaxation times for application to the infrared emission models of the upper atmospheres of outer planets and Titan

    Get PDF
    The 7.8 micrometer emission from the nu(sub 4) band of methane (CH4) is a regularly observed feature in the stratosphere of all the giant planets and Titan. On Jupiter, enhancements in this emission are associated with the infrared hot spots in the auroral zone. Attempts to model this phenomenon in particular, and to understand the role of methane in general, have been hampered in part by a lack of adequate laboratory measurements of the collisional relaxation times for the nu(sub 3) and nu(sub 4) levels over the appropriate temperature range. To provide this needed data, a series of laboratory experiments were initiated. In the experimental arrangement the nu(sub3) band of methane is pumped at 3.3 micrometers using a pulsed infrared source (Nd:YAG/dye laser system equipped with a wave-length extender). The radiative lifetime of the nu(sub 3) level (approximately 37 ms) is much shorter than the nu(sub 4) lifetime (approximately 390 ms); however, a rapid V-V energy transfer rate ensures that the nu(sub 4) level is substantially populated. The photoacoustic technique is used to acquire relaxation rate information. The experiments are performed using a low-temperature, low-pressure cell. Experimental apparatus and technique are described. In addition some of the experimental difficulties associated with making these measurements are discussed and some preliminary results are presented

    Investigation of advanced counterrotation blade configuration concepts for high speed turboprop systems. Task 5: Unsteady counterrotation ducted propfan analysis. Computer program user's manual

    Get PDF
    The primary objective of this study was the development of a time-marching three-dimensional Euler/Navier-Stokes aerodynamic analysis to predict steady and unsteady compressible transonic flows about ducted and unducted propfan propulsion systems employing multiple blade rows. The computer codes resulting from this study are referred to as ADPAC-AOACR (Advanced Ducted Propfan Analysis Codes-Angle of Attack Coupled Row). This report is intended to serve as a computer program user's manual for the ADPAC-AOACR codes developed under Task 5 of NASA Contract NAS3-25270, Unsteady Counterrotating Ducted Propfan Analysis. The ADPAC-AOACR program is based on a flexible multiple blocked grid discretization scheme permitting coupled 2-D/3-D mesh block solutions with application to a wide variety of geometries. For convenience, several standard mesh block structures are described for turbomachinery applications. Aerodynamic calculations are based on a four-stage Runge-Kutta time-marching finite volume solution technique with added numerical dissipation. Steady flow predictions are accelerated by a multigrid procedure. Numerical calculations are compared with experimental data for several test cases to demonstrate the utility of this approach for predicting the aerodynamics of modern turbomachinery configurations employing multiple blade rows

    The Lillie Mae: A Capital Investment Project In Riverboat Restoration

    Get PDF
    This case involves a proposed capital investment project. It was written for use in an introductory business finance course to present students a capital budgeting scenario involving elements of both an expansion project and a replacement project that is more complex than the usual textbook problems. It also provides students an exercise in the application of standard spreadsheet software to a common analytical problem in corporate finance, namely, a proposed capital expenditure

    The Lillie Mae: A Capital Investment Project In Riverboat Restoration

    Get PDF
    This case involves a proposed capital investment project.  It was written for use in an introductory business finance course to present students a capital budgeting scenario involving elements of both an expansion project and a replacement project that is more complex than the usual textbook problems.  It also provides students an exercise in the application of standard spreadsheet software to a common analytical problem in corporate finance, namely, a proposed capital expenditure

    A Paradox Within The Time Value Of Money: A Critical Thinking Exercise For Finance Students

    Get PDF
    This study presents a paradox within the time value of money (TVM), namely, that the interest-principal sequence embedded in the payment stream of an amortized loan is exactly the opposite of the interest-principal sequence implicit in the present value of a matching annuity.  We examine this inverse sequence, both mathematically and intuitively, and argue that it provides an excellent exercise for finance students to explore, both to enhance their critical thinking skills as well as to strengthen their understanding of TVM concepts.  Additionally, such an exercise will involve them actively in the learning process, as mandated by AACSB International’s Eligibility Procedures and Standards for Business Accreditation

    Ultrasound-triggered antibiotic release from PEEK clips to prevent spinal fusion infection: Initial evaluations.

    Get PDF
    Despite aggressive peri-operative antibiotic treatments, up to 10% of patients undergoing instrumented spinal surgery develop an infection. Like most implant-associated infections, spinal infections persist through colonization and biofilm formation on spinal instrumentation, which can include metal screws and rods for fixation and an intervertebral cage commonly comprised of polyether ether ketone (PEEK). We have designed a PEEK antibiotic reservoir that would clip to the metal fixation rod and that would achieve slow antibiotic release over several days, followed by a bolus release of antibiotics triggered by ultrasound (US) rupture of a reservoir membrane. We have found using human physiological fluid (synovial fluid), that higher levels (100–500 μg) of vancomycin are required to achieve a marked reduction in adherent bacteria vs. that seen in the common bacterial medium, trypticase soy broth. To achieve these levels of release, we applied a polylactic acid coating to a porous PEEK puck, which exhibited both slow and US-triggered release. This design was further refined to a one-hole or two-hole cylindrical PEEK reservoir that can clip onto a spinal rod for clinical use. Short-term release of high levels of antibiotic (340 ± 168 μg), followed by US-triggered release was measured (7420 ± 2992 μg at 48 h). These levels are sufficient to prevent adhesion of Staphylococcus aureus to implant materials. This study demonstrates the feasibility of an US-mediated antibiotic delivery device, which could be a potent weapon against spinal surgical site infection. Statement of Significance: Spinal surgical sites are prone to bacterial colonization, due to presence of instrumentation, long surgical times, and the surgical creation of a dead space (≥5 cm 3 ) that is filled with wound exudate. Accordingly, it is critical that new approaches are developed to prevent bacterial colonization of spinal implants, especially as neither bulk release systems nor controlled release systems are available for the spine. This new device uses non-invasive ultrasound (US) to trigger bulk release of supra-therapeutic doses of antibiotics from materials commonly used in existing surgical implants. Thus, our new delivery system satisfies this critical need to eradicate surviving bacteria, prevent resistance, and markedly lower spinal infection rates
    • …
    corecore